Sign In | Join Free | My tjskl.org.cn
China TS Lightning Protection Co.,Limited logo
TS Lightning Protection Co.,Limited
Start Future From Safety NO LIGHTNING ACCIDENT IS ALLOWED
Active Member

8 Years

Home > Voltage Surge Suppressor >

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

TS Lightning Protection Co.,Limited
Contact Now

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

Model Number : TS-230M5RM

Brand Name : TSTLP

Place of Origin : Guangdong,China

Certification : CE Compliance

MOQ : Negotiable

Price : Negotiable if good quantity

Packaging Details : By standard export box/carton

Delivery Time : Around 7 working days upon receipt of payment

Payment Terms : 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead

Supply Ability : 2000 sets/month

Un : 230V

Uc Optional : 30V / 60V / 75V / 150V / 320V

Normal Discharge Current : 5kA

Type of remote signalling contact : Break contact

Test Standards : IEC 61643-11

Certified : CE

Contact Now

24v / 48v / 60v / 120v / 220v / 230v Type 3 Transient Surge Suppressor

TS-230M5RM Class III transient surge suppressor is designed as per IEC 61643-11 to install at LPZ 1-2 or higher as fine protection for electronic devices. e.g. icebox, air conditioner, photocopy, communication equipment, network equipment... various power supply system

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

Relative 150Vdc / 600Vdc / 750Vdc / 1000V DC Surge Protection Device for photovolatic protection.

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

  • Type 3 Surge Protector Technical Data
Model No. TS-230M5RM TS-120M5RM TS-60M5RM TS-48M2RM TS-24M2RM
Normal a.c. Voltage Un 230V 120V 60V 48V 24V
Rated voltage (max.a.c. continuous voltage) Uc 320V 150V 75V 60V 30V
Rated voltage (max.d.c. continuous voltage) Uc 320V 150V 75V 60V 30V
Normal Current IL 16A 16A 16A 16A 16A
Nominal discharge current (8/20, L-N) In 3 kA 2.5 kA 2.5 kA 1 kA 1 kA
Nominal discharge current (8/20, L+N-PE) In 5 kA 5 kA 5 kA 2 kA 2 kA
Combination wave (L-N) Uoc 6 kV 6 kV 6 kV 2 kV 2 kV
Combination wave (L+N-PE) Uoc 10 kV 10 kV 10 kV 4 kV 4 kV
Voltage protection level(L-N) Up ≤1.15 kV ≤0.7 kV ≤0.5 kV ≤0.35 kV ≤0.2 kV
Voltage protection level(L+N-PE) Up ≤1.5 kV ≤1.1 kV ≤0.85 kV ≤0.85 kV ≤0.85 kV
Response time tA ≤25ns (L-N); ≤100ns(L+N-PE)
Max. back up fuse 16A gL/gG
Operating temperature range Tu -40°C...+80°C
Short-circuit withstand capability at max.backup fuse 6kArms
Relative humidity: ≤95% (25°C)
Cross-sectional area 0.5mm2 ~ 6mm2 solid / 4mm2 flexible
Mounting on 35mm2 DIN rail
Enclosure material Red thermoplastic, UL94-V0
Standards IEC 61643-11; GB 18802.1; YD/T 1235.1
Type of remote signalling contact Break contact
Switching capacity UN/IN AC:250V/0.5A DC:250V/0.1A,125V/0.2A,75V/0.5A
Cross-sectional area for remote signalling contact Max. 1.5mm2 solid / flexible
Compliance CE (LVD, EMC)

  • Main Character
  1. Class 3 transient surge suppressor with LIGHT indications: Green - OK, red - Fault
  2. Single-phase surge protection and with disconnector
  3. Remote signalling connector for fault indication
  • INSTALLATION STEPS
  1. Mount the transient surge suppressor on 35 mm DIN rail.
  2. Connect conductors, the cross-sectional area of cable must be larger than 4mm2 . The withstand voltage value of cable is not smaller than AC500V; ensure wiring reliable.
  3. If Remote Alarm needed, it s/b connected signal lines to remote signal terminal 1 and 2 connected.
  4. After above, switch on the power supply and turn on the circuit breaker, if the transient surge suppressor’s indicator light displays green,this indicates the unit is operating normally.

Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the transient surge suppressor's indicator light displays red, electrician should check/replace the transient surge suppressor.

  • Installation Diagram

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

  • Real Type 3 Surge Protection Device Installation

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

PDF Catalog Download - TSTLP 24~230V Type 3 SPD.pd...

Tag: transient surge suppressor


Product Tags:

transient surge suppressor

      

3 phase surge suppressor

      
Quality Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v for sale

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: TS Lightning Protection Co.,Limited
*Subject:
*Message:
Characters Remaining: (0/3000)